Search This Blog

Thursday, March 9, 2017

4GB CT Dicom case:  optimized memory during the Dicom load and enabled the compression.  This reduced memory consumption by x5 and speed  x2+  during the DICOM load.

Tuesday, March 7, 2017

AutoFocus3D  dialog box:   fixed the Tab order of the controls.
Fixed the PainBrush error when the nothing can be drawn\erased on any timepoint except t0.

Monday, March 6, 2017

Moved the Register4D menu item to under the General Register menu.

1. Registration cross-correlation measure:   Fixed defect when either Source or Target were completely = 0
This was causing an infinite loop during the registration.

2.  Added general warning for all registration measure if the partial result of calculation was NAND.


Sunday, March 5, 2017

Registration of PET-MR exam (from Jean Logan):  

1. PET:  Perform "MainMenu>3D Projection>Mirror voxels"
2. Perform EdgeWave BrainMask detection on Axial  using the "MainMenu>Segment>Axial BrainMask"
3. After selecting the last timepoint of PET as the base for the registration, using the MR+BrainMask as the target, performed registration using the CrossCorrelation measure.





Friday, March 3, 2017

Paintbrush drawing defect:   Fixed the crash when after minute or so of intensive drawing the FVX was crashing.
Fixed the Crash defect:   MagTrace tool starts + Ctrl button.
Concentration Conversion dialog:
When User changes the concentration conversion method,  only the fields related to this active method would become enabled.  The rest of the fields would be grey.


Thursday, March 2, 2017

Sunday, February 26, 2017

Thursday, February 23, 2017

Whole Breast segmentation.  Added a Skin Peel procedure that removes a 5mm layer contacting the Air.  This should eliminate the problem at the following step of FGT\FAT separation.

FireVoxel Buld 233 is released.

Wednesday, February 22, 2017

Fixed cluster of the defects related to K-trans "invalid units" report:

1.  Fixed the Unit validation function to include all the units available in ALL models.
This defect was also present in IVIM, ADC etc in about dozen of models.

2. Fixed the defect when reading the units from .IM file (treat the line end "\n") properly.

Tuesday, February 21, 2017

LayerControl dialog box> Load DICOM button:  extended functionality so several DICOM volumes could be opened WITHOUT closing the OpenDicom dialog and regenerating the DICOM tree.
It is similar to DICOM Document Multi-Load

Tuesday, February 14, 2017

Updated the logic for the Title of the "Full DICOM Info for the selected item" inside the OpenDialog dialog.
Note: an identical dialog also can be called from the LayerControl dialog.  In that context it will display the current Time and Slice index of the volume.

Monday, February 13, 2017

Friday, February 3, 2017

Implemented the DrawViewCache for individual Volume entity that holds the snapshots for all Views (windows) containing the present Volume.  F.e. this is very important for multiprojection views, say 3 projections, would be all repainted from the separate cache.  This speeds up many operations, such as 3D Paintbrush and constructing of VROI on multiprojection views.

This also takes care of reported defects with FilmView and other slice display,