1. Implemented fix when the TAC txt file was crashing the "Open Tac as 4D volume" function.
2. Model #4 - added hyperparameters {Start,End} to process only the range of points.
Search This Blog
Monday, May 28, 2018
Tuesday, May 15, 2018
Build 274 is released.
1. Algorithmic work for Lung GRASP 4D fully automatic segmentation. Working on 5 cases of Deep+Normal breathing trying to achieve a good result so lung spirometry measurements can be performed.
2. Fixed the memory leak in Bical function.
3. Corrected the allocated size of each memory block for Volume slice, so it is no more than required. It also resulted in smaller system memory use and accurate resource usage reporting.
4. BiCal with "Output Field" option now otput "double precision Real" volume.
5. Fixed defect when volume is converted to isotropic for processing and then back to original resolution, so there are no void voxels on the fringe.
6. BiCal\EdgeWave front age calculation: fixed defect occurring in 1-voxel margins of the volume. This was resulting in unpleasant margin artefacts in BiCal.
7. Fixed memory leak in DetectRelativeRidge function.
8. Detected and removed all memory leaks from Lung\Trachea 4D segmentation.
9. Optimized speed of MemVol -> SetBox -> (MemVol) function which is the basis of many other
functions. This reduced the time of Lung segmentation results construction (not segmentation itself) x3 times.
10. Parallelized CreateBasicDicomHeader function which is basis of many functions on UI.
1. Algorithmic work for Lung GRASP 4D fully automatic segmentation. Working on 5 cases of Deep+Normal breathing trying to achieve a good result so lung spirometry measurements can be performed.
2. Fixed the memory leak in Bical function.
3. Corrected the allocated size of each memory block for Volume slice, so it is no more than required. It also resulted in smaller system memory use and accurate resource usage reporting.
4. BiCal with "Output Field" option now otput "double precision Real" volume.
5. Fixed defect when volume is converted to isotropic for processing and then back to original resolution, so there are no void voxels on the fringe.
6. BiCal\EdgeWave front age calculation: fixed defect occurring in 1-voxel margins of the volume. This was resulting in unpleasant margin artefacts in BiCal.
7. Fixed memory leak in DetectRelativeRidge function.
8. Detected and removed all memory leaks from Lung\Trachea 4D segmentation.
9. Optimized speed of MemVol -> SetBox -> (MemVol) function which is the basis of many other
functions. This reduced the time of Lung segmentation results construction (not segmentation itself) x3 times.
10. Parallelized CreateBasicDicomHeader function which is basis of many functions on UI.
Wednesday, May 2, 2018
FireVoxel Build 273 is released.
1. Corrected Multi-modal registration using crosscorrelation measure.
2. Restored the ABT test for Registrations.
3. NIFTI File Load\Save: enabled writing the modality name into the "description" field of the
NIFTI header.
4. ANALYZE file format File Load\Save: enabled writing the modality name into the "description" field of the NIFTI header.
5. Enabled NIFTI Save\Load of 64-bit Real volume data.
6. Implemented corrections to the "Manual\Automatic" Concentration baseline calculations.
7. Implemented ABT subtest for the Lung\Trachea 4D segmentation
8. Implemented new Concentration converison method (S/S0-1)/(CR*T1)
1. Corrected Multi-modal registration using crosscorrelation measure.
2. Restored the ABT test for Registrations.
3. NIFTI File Load\Save: enabled writing the modality name into the "description" field of the
NIFTI header.
4. ANALYZE file format File Load\Save: enabled writing the modality name into the "description" field of the NIFTI header.
5. Enabled NIFTI Save\Load of 64-bit Real volume data.
6. Implemented corrections to the "Manual\Automatic" Concentration baseline calculations.
7. Implemented ABT subtest for the Lung\Trachea 4D segmentation
8. Implemented new Concentration converison method (S/S0-1)/(CR*T1)
Subscribe to: