FGT Batch dialog, initial layout. It is similar to CT batch processing layout.





1.  Source folder specifies where the folder containing the FVX files is.  It might have  subfolders.
2. Output masks:
    2a) checkbox specifies if they have to be output
    2b) Location specifies where the masks go
3,  Output log specifies output text file.

FireVoxel Build 200

1. Fixed entropy calculation
2. Fixed crash defect: in Dialog Open DICOM:  when Browse functionality is used to change the DICOM folder, pressing the Info button causes the crash.
3. DICOM open dialog:   fixed the loading problem when very long path of the DICOM file is specified.
4. N3-nonuniformity correction tool - enabled to work with Real-valued volumes.
5. Enabled BiCal to work with the Real-value images. Processed sodium image with BiCal.
6. Fixed the "total non-function" defect in VA_VolMul (Volume Multiply) function. This was used in Sulci Depth detection and BiCal.
7.Implemented initial version of perivascular space segmentation under "MainMenu>Segment>Detect Bright Spots" with the Dialog.

N3-nonuniformity correction tool - enabled to work with Real-valued volumes.