Build 431A is released.
1. Batch module report correction (NIH tag fix)
Build 430 is released.
1. Updated the model #18: "Basic IVIM".
2. Implemented IVIM model #54 based on the "Whole Solution Space" engine.
3. Model #53: Provided the conversion function from specified COD to RMSE so it is could be supplied as the SolEps to the Optimization (typical used COD value = 0.999)
4. Added the working resolution option for Radiomics2D : Individual\Batch processing.
TO ACTIVATE Radiomics2D for INT Maps:
1. Main Menu>Applications>Integer Map Batch Feature Analysis.
2. Dialog will appear to specify the folder (full of FVX files with several layers).
3. After short analysis a dialog box will appear which will show "various" for layer names.
4. At this point you can change the histogram binning common to all cases (fvx files).
5. Press "Features" to select the desire Radiomics features.
6. Note "Working Resolution (mm)" edit box. Leave default "0" to process layers at their current resolution.
OR Specify a different working resolution. All images will be converted to the specified Isotropic resolution (this would not be shown to the User explicitly).
FireVoxel Build 427 is released.
1. WML segmentation : Implemented batch job based on FVX files as a source.
2. Ground Truth evaluation batch on a set of FVX files.
3. New Algorithm (4) for WML segmentation based on WM\WML signal estimation.
4. WML segmentation : Fixed the crash when MPRAGE volume is used.
Build 424 is released
1. New optimization GOWSS engine is released that returns the entire solution space approximation.
2. Correction in EdgeWave "Mark Grow Start Voxels" function, removed the parallel_for construct.
3. New EdgeWave function : GrowROIintoConstraint.
4. Implemented a new variant of WML segmentation (Algo2).
Build 423 is released.
1. WML processing: WM layer added to output as a new layer (both single and batch variants).
2. WML algorithm: changed the way the LVinfl is used. Now the GM mask generated explicitly, then LVinfl is subtracted from GM.
3. Re-arrangement of the WML dialog box.
4. WML : added a function to remove the brain stem
Build 421 is released.
1. Fixed the crash when Saving FvX file, the dialog press Cancel button.
2. Fixed defect in EdgeWave algorithm, when running in 2D Mode. Defect was the empty mask because each slice was treated as 3D volume.
3. Implemented a prototype V1 of Heart Segmentation from CT.
4. Implemented custom DICOM scaling when loading the parametric maps generated by Siemens software.
5. Implemented File>Open Single DICOM File function.