Search This Blog

Wednesday, March 4, 2015

Dynamic (4D) Segmentation  Verification dialog box:  added the Mouse Wheel response so user can scroll through slices without exiting the dialog box.

Tuesday, March 3, 2015

Renal GFR calculation (CERENE) - changed the default registration method to URAL (signal  gradient based).
Dynamic segmentation dialog: modified the dialog layout and added several addition options for the TAC normalization and comparison.

Monday, March 2, 2015

FireVoxel Build 175 is released.
NIFTI-1 support:  enable  FireVoxel load of images from the BPD dataset

Provided initial support for reading Nifti-1 format into FireVoxel.
Preliminary testing was done on sample files from NIFTI website
a)  3D   unsigned 8-bit
b)  4D  signed 16-bit

Sunday, March 1, 2015

PET4D-MR4D registration:  added a content time difference check between MR-PET and an option to "not use the DICOM-tags initial alignment".  This is to fixed some studies where PET & MR were acquired not simultaneously.

Now correct result for RS registration:

When PET document is loaded, the times are now correctly recorded in absolute format (i.e. from 01/01/1900)

Saturday, February 28, 2015

Case CV:
Quality of PET4D-MR4D registration (Binary mode).  PET and MR should be motion corrected prior to the registration.


Registration by DICOMTAGS: corrected defect when two  4D volumes are registred and placing as an additional layer produces a crash.

Thursday, February 26, 2015

Fixed defect:  When multilayer document is cropped using Vector ROI, new document opens and ALL the layers are redrawn correctly now.
FireVoxel Build 174 is released.

Download here:   

https://drive.google.com/file/d/0B2lI9iEKOqv6ZkxLbGx2aWJBWWM/view?usp=sharing
FireVoxel 174 and higher was compiled with Visual Studio 2013.  It requires a one time installation of a new Visual Studio 2013 redistributable package.

It is available from Microsoft here:
http://www.microsoft.com/en-us/download/details.aspx?id=40784

Press Download button.

Then choose "vcredist_x86.exe"



Created a dedicated workflow submenu:  "MainMenu>Application>Renal workflow without AIF"

Wednesday, February 25, 2015

Tuesday, February 24, 2015

Get ROI Tac (RoiStats4D\F4) procedure: optimized performance so the speed is proportional to the size of the ROI.
Implemented UI-level function "Main Menu>ROI>Crop volume by ROI".  This takes {3D,4D} ROI, find maximum bounding box for all voxels and crops the current document by this box in 4D creating a new document.
Kidney Ctx+Mdl segmentation from GRASP-4D exam.  FVX registration is performed in this example.


Timepoint of cortex peak


Kidney GRASP-4D (from liver exam).  Fully automatic 4D-segmentation.