Search This Blog
Sunday, November 2, 2014
Friday, October 31, 2014
Non-Uniformity Normalization Using 3D Canny Edges and Legendre Polynomial Approximation of the Bias Field: Validation on 7T T1W Brain Images. ISMRM 2013. Artem Mikheev, Henry Rusinek, Graham Wiggins.
Ultra High Field MRI: What is in Full Bloom & What is Sprouting? ISMRM SCIENTIFIC
WORKSHOP 2013. Artem Mikheev, Henry Rusinek, Graham Wiggins.
![]() |
| Original (Non-uniformity: WM=28.5% GM=33.5%) |
![]() |
| N3-corrected (field smoothness = 10mm. Nonuniformity WM=13.5% GM=19.8%) |
![]() |
| BiCal (Nonuniformity: WM=7.1% GM=13.4%) |
All acquisitions were performed on a 7T imager (Magnetom;
Siemens, Erlangen, Germany) by using a volume-transmit 24-element receive coil
array (Nova Medical, Boston, Mass). A 3D automatic shimming was first performed
by adjusting all fist and second order shim currents, then shim performance was
verified by using the interface on the imager console. This was followed by
either sagittal (n=2) or axial (n=2) 3D MPRAGE sequences acquired on four
volunteers (28-54 year old, 3 males). The acquisition parameters were:
TR/TE/TI=2.6/2600/1100 msec, FA=6°, 248
SL=0.6 mm, 346 × 323 x 248 matrix, acceleration factor of two.
Thursday, October 30, 2014
FireVoxel Build 158 is released.
1. Implemented an initial version of the fully
elastic registration algorithm. In this variant - a 3D volume and the
"Starting Shape" ROI are provided.
2. ROI Inflate-Deflate dialog box: encapsulated programming
interface.
3. URAL feature generation function
(both Grad\Edge). Made adjustment to algorithm that greatly improve the
speed of the processing on binary volumes (was done in context of the
Mongoose-Elastic registration)
4. Landmark
Matching\Registration function: upgraded to accept arbitrary number of
Landmarks.
5. Added a handy function to determine
if 3D polynomial transform is actually 2D.
6. Performed correction for the
"Calculate the Texture Gradient over the ROI only" function.
7. Finalized, documented and sealed
2 most promising variants of the new Elastic Mongoose registration\segmentation
algorithm.
8. BrainPrint - SulciBasePrint: Can
be now generated in FireVoxel directly.
9. Added ".image"
to the list of the supported DICOM extensions.
10. Liver DCDI: Blood Vessel
removal Dialog: corrected an error with displaying the percentage of the Vessel
and Liver.
11. Performed a major reengineering
of a composite DynamicCoordinate structure in FireVoxel
12. FVX file format load:
Implemented function that ensures the Chronological order of Dynamic
coordinates.
13. Fixed an error in
"ChangeEndianess" function that was causing an aborted load of .im
files.
14. .IM file RAW load: added
special processing in case the time values are not in chronological order.
15. MIDAS .time format::
Added improved heuristic about the "Starting Index Convention"
16. T1-inversion recovery
model: completely reengineered the model, implemented a Global Fit
solution, updated the user interface.
17. "Brain EdgeWave
Express" workflow: corrected the aborted processing defect when
submitted volume is 4D.
18. PET-MR 4D-4D
registration: complete re-engineering of calculations and User interface.
19. Speed up and minor corrections
to the "T1-inversion recovery" parametric models
Wednesday, October 29, 2014
Tuesday, October 28, 2014
Monday, October 27, 2014
Sunday, October 26, 2014
Subscribe to: