Search This Blog
Wednesday, March 19, 2014
YL-case, "DCDI - Stabilized V1"
Obtained a good fit with good parameter values except for the high flow. Perhaps high flow can be explained by the concentration conversion.
Note1: ROI was drawn fairly large as in Sourbron's paper (i.e. 40-60 mm diameter)
Note2: As in Sourbron's paper the Arterial delay exceeds the Venous delay. Interestingly that would
mean that venous contrast arrives first, but this is exactly his primary mode.
Obtained a good fit with good parameter values except for the high flow. Perhaps high flow can be explained by the concentration conversion.
Note1: ROI was drawn fairly large as in Sourbron's paper (i.e. 40-60 mm diameter)
Note2: As in Sourbron's paper the Arterial delay exceeds the Venous delay. Interestingly that would
mean that venous contrast arrives first, but this is exactly his primary mode.
Tuesday, March 18, 2014
Monday, March 17, 2014
Sunday, March 16, 2014
Quick FireVoxel Builds 132B, 132C are released reflecting the urgent work on the stabilization of the Liver DCDI (Dual compartment dual input models).
Particularly, in 132C, a "DCDI Stabilized - V1" is introduce. It uses the integral form of DCDI equation to eliminate one of the independent optimization variables thus stabilizing the fit.
Particularly, in 132C, a "DCDI Stabilized - V1" is introduce. It uses the integral form of DCDI equation to eliminate one of the independent optimization variables thus stabilizing the fit.
Friday, March 14, 2014
Thursday, March 13, 2014
Wednesday, March 12, 2014
Dialog RoiStats4D: User is now able to use {LEFT,RIGHT} keyboard keys to scroll in time when this dialog is open. The 4D volume and the Curves in the dialog box are updated correspondingly.
Among many uses this function allows to reuse this dialog in the BAT (Bolus Arrival Time) verification procedure.
Among many uses this function allows to reuse this dialog in the BAT (Bolus Arrival Time) verification procedure.
Monday, March 10, 2014
Liver DCDI model: adding two implementations of this model to the UI.
The "Standard" variant, has exact implementation of the Sourbron's paper with the addition of the Exam length parameter and the variables {TotalFlow,fa,Ve,ki}.
The "Experimental" variant hosts new investigations, such as independently derived "Ta" arterial delay time.
The "Standard" variant, has exact implementation of the Sourbron's paper with the addition of the Exam length parameter and the variables {TotalFlow,fa,Ve,ki}.
The "Experimental" variant hosts new investigations, such as independently derived "Ta" arterial delay time.