Build 410A is released.
1. Addressed FireVoxel document Load|Save speed issues.
Build 410 is released.
1. Compiled and link the latest DCMTK 3.6.7 as DLLs. Static libs (non-DLL) linkage is not working at the moment. Posted a request at the developers forum.
2. Fvxdcm_DC.cpp : corrected the handling of VR_AS and VR_UI.
3. Deep verification of FVX file save: in addition to byte-for-byte comparison with the internal MemFile, we also reload the FVX document and compare it on the entity level.
4. FVX file now contains the Build# that created it.
5. Finally linked DCMTK 3.6.7 statically (by fixing CMake script defect)
Build 409 is released.
1. New codec for REAL volumes as FVX entity. Substantial improvement over the previous codec.
2. When FVX document saved, the REAL volume entity is always saved compressed independently of the UserOptions settings for compression state. This is to simplify the optimal saving of the files and minimizing storage\transfer times.
Build 408 is released
1. Lung Segmentation : added the "Minimal Slice Thickness" parameter to the dialog and processing. This helps to remove elongated protrusions.
2. Bical NUC: enabled processing on single slice volumes when other than {VA_BICALSEG_GRAD} style is selected.
3. FVX document load : fixed the defect when "Load Dynamic Model" option = FALSE. This also fixed the defect when BM2 module was not able to update the batch models.
4. Added [MinVal,MaxVal] to the list of "First Order Radiomics features".
5. When outputting the Radiomics measurements : if only the First Order features are specified we don't out the GLMsys and Distance settings.
6. Loading various curves throughout the FireVoxel (several function) : removed the fixed limit {10K} on the number of allowed timepoints.
7. Optimized the LoadTacFile function to accommodate very large number of timepoints. Added the progress bar.
8. Provided menu item "Curve basic measurements".
9. Adjusted Incoherence function to deal with very large number of timepoints 25K+.
10. Added the "Double-normalized Incoherece" and the "Incoherence Period" to the Curve measurements.
11. Enabled loading of the SIEMENS DWI datasets where the b-value is encoded in the SequenceName (0x0018:0024)
Build 407 is released.
1. Update menu for the Single Slice Lung MR segmentation workflow.
2. Lung Single slice "Segment Current Timepoint" function was added with tuned parameters.
3. Lung curve measurement : introduced the Normalized Incoherence measure so it potentially could be better compared to Incoherence of the pilot tone curve (which comes in normalized).
4. Lung 4D Segmentation dialog : added the option "Correct Fringes".
5. ABT subtest for : "Lung MR Segmentation on Current Timepoint"
6. Produced a mini manual for the Lung workflow changes
https://youtu.be/5tfV8z-Sa5g
Build 406 is released.
1. Implemented new Workflow: "Parametric Map Batch Feature Processing". FireVoxel opening the folder containing FVX files. Then common parametric maps are identified. Radiomics feature measurements are performed on all files in the folder and result is placed into TXT file formatted for Excel import.
2. DICOM file loading of b-values: Included the code check for using the DICOM-recommended tag before proceeding to the Manuf\Model-specific private tags. (Resolved the issue with the Philips\Activa images).
3. Loading an odd Diffusion DICOM set is facilitated by introducing a new option (checkbox) "Combine STUDIES" in DICOM load Dialog Box.